Czy chcesz skorzystać z naszego narzędzia Konfigurator produktów, aby skonfigurować produkt przed dodaniem do koszyka? Jeśli nie, dodaj go bezpośrednio do koszyka.
Practice report: New chlorine dioxide sensor for monitoring disinfection
Author:Bernd Schoemaker, Head of Laboratory, Wassergewinnung Essen GmbH. Wassergewinnung Essen GmbH (WGE), a subsidiary of Stadtwerke Essen AG and Gelsenwasser AG, operates two drinking water plants with an annual production volume of about 65 million cubic metres. The drinking water is obtained by the costly treatment of surface water. To monitor the water quality, water quality stations containing instruments that measure chlorine dioxide are operated in the pumping works. On the basis of the experience gained in the trial described in this report, one of the old chlorine measuring instruments was replaced by a new HACH LANGE ClO2 sensor. 4 pages
English UK
792 KB
2008-04
Sprawozdanie z eksploatacji: Nowy czujnik dwutlenku chloru do kontroli dezynfekcji
Author:Bernd Schoemaker, Head of Laboratory, Wassergewinnung Essen GmbH. Wassergewinnung Essen GmbH (WGE), a subsidiary of Stadtwerke Essen AG and Gelsenwasser AG, operates two drinking water plants with an annual production volume of about 65 million cubic metres. The drinking water is obtained by the costly treatment of surface water. To monitor the water quality, water quality stations containing instruments that measure chlorine dioxide are operated in the pumping works. On the basis of the experience gained in the trial described in this report, one of the old chlorine measuring instruments was replaced by a new HACH LANGE ClO2 sensor. 4 pages
Polish
796 KB
2008-04
Apr08
Arkusze danych
Rodzaj
Język
Rozmiar
Data
Wydanie
Nowe czujniki amperometryczne do pomiarów chloru wolnego,ClO2 oraz O3
Czujniki amperometryczne,... Amperometric sensor, process analysis, measurement of free chlorine, ozone and chlorine dioxide with the sensors 9184 sc, 9185 sc, 9187 sc, basic description, picture included: dissociation curve, time of breakdown of dissolved ozone, graphic of application usage, technical data, ordering information; 4 pages