EZ4006 Chloride Analyser

EZ4006 Chloride Analyser
Nr produktu: EZ4006.XXXXXXXX
Cena jednostkowa Kontakt

Zawartość opakowania

EZ4006 Chloride Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x mV electrode, 2 x empty 10L Reagent Containers with Fittings (for Cleaning & Buffer Solution) and 1 x empty 10L Reagent Dark Container with Fittings (for AgNO₃ Solution)

Parametry techniczne

Alarmy: 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Certyfikaty: CE compliant / UL certified
Ciśnienie próbki: By external overflow vessel
Czas cyklu: 10 - 15 minutes
Demineralised water: For rinsing / dilution
Earth connection: Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Gwarancja: 24 miesięcy
Instrument air: Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
Jakość próbki: Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Kalibracja: N.A.
Klasa ochrony: Protection class: Analyser cabinet: IP44 / Panel PC: IP65
Liczba strumieni próbki: 1, 2, 4 or 8
Limit detekcji: 5 mg/L
Materiał: Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Metoda pomiarowa: Potentiometric titration with silver nitrate (AgNO₃), conform with standard method APHA 4500-Cl (D)
Model: EZ4006
Nazwa metody: Titrimetric
Odpływ: Atmospheric pressure, vented, min. Ø 32 mm
Parametr: Chloride
Pobór mocy: 100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Precyzja: Better than 2% full scale range for standard test solutions
Prędkość przepływu: 100 - 300 mL/min
Reagent Requirements: Keep between 10 - 30 °C
Temperatura otoczenia: 10 - 30 °C ±4 °C deviation at 5 - 95% relative humidity (non-condensing)
Temperatura próbki: 10 - 30 °C
Validation: Automatic; frequency freely programmable
Waga: 25 kg
Wyjścia analogowe: Active 4 - 20 mA max. 500 Ohm load, standard 1, max. 8 (option)
Wyjścia cyfrowe: Optional: Modbus (TCP/IP, RS485)
Wymiary (wys. x szer. x głęb.): 690 mm x 465 mm x 330 mm
Zakłócenia: Bromide, sulphide, iodide ions may interfere. Ferricyanide causes high results and must be removed. Chromate and dichromate interfere and should be reduced to chromic state or removed. Ferric iron interferes if present in an amount substantially higher than the amount of chloride. Chromic ion, ferrous ion and phosphate do not interfere. Fats, oil, proteins, surfactants and tar.
Zakres pomiarowy: 25 ‐ 500 mg/L
  25 - 500 mg/L Cl-

Optional:
5 - 50 mg/L Cl-
5 - 125 mg/L Cl-
5 - 250 mg/L Cl-
Internal dispenser dilution (max. factor 100)
Zasilanie: 100 - 240 VAC, 50/60 Hz
Zawartość opakowania: EZ4006 Chloride Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets, 1 x mV electrode, 2 x empty 10L Reagent Containers with Fittings (for Cleaning & Buffer Solution) and 1 x empty 10L Reagent Dark Container with Fittings (for AgNO₃ Solution)