Certyfikaty elektryczne:
EMC
CE compliant for conducted and radiated emissions:
- CISPR 11 (Class A limits)
- EMC Immunity EN 61326-1 (Industrial limits)
Safety
CAN/CSA C22.2 No. 61010-1
cETLus safety mark for:
- General Locations per ANSI/UL 61010-1 & CAN/CSA C22.2. No. 61010-1
Czas odpowiedzi:
< 60 s
Dostępne oprogramowanie:
Cloud (Claros-enabled)
Funkcje przekaźnika:
Scheduler (Timer), Alarm, Feeder Control, Event Control, Pulse Width Modulation, Frequency Control, and Warning
Interwał konserwacji:
Monthly: Calibration and reagent refill
Komunkacja:
Analog:
Five 0-20 mA or 4-20 mA analog outputs on each analog output module
Up to two analog Input modules (0-20 mA or 4-20 mA). Each input module replaces a digital sensor input.
Digital:
Profibus DPV1 module
Modbus TCP
Profinet IO module
Ethernet IP module
Liczna kanałów:
1
Limit detekcji:
Drift is negligible; 1 ppb
Materiał:
Counter-Electrode: Stainless steel; Working Electrode: Platinum
Odczynnik:
Sample conditioning with diisopropylamine, ammonia, or diethylamine
Opcje komunikacji:
Claros Ethernet IP
Połączenie linii odpływu:
6 x 8 mm (tubing must not exceed 4 feet and must drain straight down)
Połączenie linii próbki:
4 x 6 mm stainless steel tubing
Powtarzalność:
± 2% or 1 ppb (whichever is greater)
Poziomy ochrony:
2
Przekaźnik: moduł operacyjny:
Primary or secondary measurement or timer/scheduler
Przekaźniki:
Four electromechanical SPDT (Form C) contacts, 1200 W, 5 A
Przepływ:
166 - 250 mL/min (10 - 15 L/h) recommended
Ręczny wybór języka:
Bulgarian, Chinese (PRC), Croatian, Czech, Danish, Dutch, English, Estonian, Finnish, French, German, Greek, Hungarian, Italian, Japanese, Korean, Lithuanian, Polish, Portuguese (Brazil), Portuguese (Portugal), Romanian, Russian, Slovak, Slovenian, Spanish, Swedish, Thai, Turkish
Referencje:
Ag/AgCl electrode with electrolyte KCl 0.1 M
Temperatura próbki:
5 - 45 °C
Waga:
14.6 kg
Warunki przechowywania:
-20 - 70 °C, 0 - 95% relative humidity, non-condensing
Wilgotność względna:
10 - 90% relative humidity (non-condensing)
Wymagania próbki:
Sample needs to be free of undissolved matter.
Wymogi energetyczne (napięcie):
110 - 240 VAC
Zakres ciśnienia:
0.5 - 6 bar (7.2 - 87 psi) or 12 L/h
Zakres pomiarowy:
0 - 100 ppb carbohydrazide (also known as ELIMIN-OX); programmable
ELIMIN-OX is a registered trademark of Nalco Chemical Co., Naperville, IL.
0 - 500 ppb hydrazine; programmable
0 - 500 ppb hydrazine; programmable
Zakres temperatury pracy:
5 - 45 °C at 0 - 95% relative humidity (non-condensing)
Zasilanie:
Without power cord
Zawartość opakowania:
Controller installed in Panel, Working Electrode, Reference Electrode, Counter Electrode, Basic User Manual