CLT10 sc Total chlorine sensor, pH combination sensor (on panel)

CLT10 sc Total chlorine sensor, pH combination sensor (on panel)
Nr produktu: LXV45B.98.22022
Cena jednostkowa Kontakt
W ciągu 2 tygodni

Compatible with Hach's "Plug and Play" Digital Controllers

The CLF10 sc and CLT10 sc Chlorine Analysers are designed to be used with all Hach digital SC controllers. Set up is fast and easy, and the system is compatible with the full line of Hach digital sensors.

No Reagent Replacement, No Waste Stream

Chlorine measurement with the CLF10 sc and CLT10 sc amperometric technology eliminates the need for routine reagent replacement and waste stream management.

EPA Compliance

The CLF10 sc and CLT10 sc analysers can be used for reporting chlorine residual measurements in accordance with EPA Method 334.0. Additionally, Hach has created a suite of laboratory products and methods to help with startup and quality control procedures required for Method 334.0.

Advanced Diagnostics

CLF10 sc and CLT10 sc advanced diagnostics alert you when the process has changed or the instument needs servicing. Diagnostic features include the Cal Watch algorithm for warning of pH and chlorine calibration deviation and a non-contacting sample flow sensor for notification of insufficient sample flow.

Real-time Process Monitoring and Control

The CLF10 sc and CLT10 sc Chlorine Analysers allow for real-time monitoring and control of disinfection processes.

Zawartość opakowania

CL10sc Panel, 1 m Digital Extension Cable, pH Combination Sensor, Panel Manual, Chlorine Sensor Manual, pH Combination Sensor Manual

Parametry techniczne

Certyfikaty: CE compliant for conducted and radiated emissions:
- CISPR 11 (Class A limits)
- EMC Immunity EN 61326-1 (Industrial limits)
Additional certifications when connected to an sc controller
Czas odpowiedzi: Free Chlorine: 140 s or less for 90% change (T90)
at a stable temperature and pH
  Total Chlorine: 100 s or less for 90% change (T90)
at a stable temperature and pH
Długość: Sensor: 195 mm
Długość kabla: 1 m (between gateway and SC controller)
Dokładność: Free Chlorine: ± 3 % of the reference test** (DPD) at constant pH less than 7.2 (±0.2 pH unit)
  Free Chlorine: ± of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration)
  Total Chlorine: ± 10 % of the reference test** (DPD) at stable pH less than 8.5 (±0.5 pH unit from the pH at calibration)
  Total Chlorine: ± 20 % of the reference test** (DPD) at stable pH greater than 8.5
Gwarancja: 24 miesięcy
Kompatybilność przetwornika: SC200, SC1000, SC4500. All controllers sold separately
Kompensacja temperatury: Internal temperature compensation in the sensor
  Wewnętrzny układ kompensacji temperatury w czujniku
Limit detekcji: 30 ppb (0.03 ppm)
Materiał: Panel: Corrosion-resistant, fully-submersible (stainless steel, PVC, silicon rubber and polycarbonate)
Metoda kalibracji: 1-point or 2-point (zero and slope) calibration
Metoda pomiarowa: Reagentless, electrochemical, three-electrode amperometric system
Opcje: Combination pH Sensor
Opis: CLT10sc Total Chlorine Sensor, pH combination sensor (On Panel)
Parametr: Total Chlorine
pH Monitoring Required?: With combination pH sensor
Podłączenie kabla: 5 pin, M12 connector
Połączenie linii odpływu: ½" ID
Połączenie linii próbki: ¼" OD
Powtarzalność: 30 ppb lub 3%, którakolwiek jest większa
Prędkość przepływu: 30 - 50 L/h L/h (od 7,9 do 13,2 galonów/h), optymalnie 40 L/h (10,5 galona/h)
Sposób montażu: Panel or Wall Mounting
Sterownik: Panel only
Szerokość: 495.3 mm
Temperatura próbki: 5 - 45 °C
Waga: Approximately 5.5 kg
Panel and empty panel-mounted components only
Waga transportowa: W przybliżeniu 20 funtów (9,1 kg)
Warunki przechowywania: -20 °C to 60 °C dry
Współczynnik przepływu: Metric
Wymiary: Sensor Only: 195 mm x 25 mm (7.68 in x 0.98 in)
Wymogi energetyczne (napięcie): None
Zakłócenia: Free chlorine: monochloramine, chlorine dioxide, ozone, and chalk deposits.
Total chlorine: chlorine dioxide, ozone and chalk deposits
Zakres ciśnienia: 0.5 bar, no pressure impulses and/or vibrations
Zakres pH: 4 - 9 pH
Zakres pomiarowy: 0 - 20 ppm Cl₂
Zakres temperatury pracy: 0 - 45 °C
Zawartość opakowania: CL10sc Panel, 1 m Digital Extension Cable, pH Combination Sensor, Panel Manual, Chlorine Sensor Manual, pH Combination Sensor Manual