EZ1031 Phosphate Analyser (Vanadate Yellow Method) PO₄-P

EZ1031 Phosphate Analyser (Vanadate Yellow Method) PO₄-P
Nr produktu: EZ1031.XXXXXXXX
Cena jednostkowa Kontakt

Zawartość opakowania

EZ1031 Phosphate Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and 1 x empty 2.5L Reagent Container with Fittings (for Colour Solution)

Parametry techniczne

Alarmy: 1 x malfunctioning, 4 x user-configurable, max. 24 VDC/0.5 A, potential free contacts
Automatyczne czyszczenie: Tak
Certyfikaty: CE compliant / ETL certified
Ciśnienie próbki: By external overflow vessel
Czas cyklu: 10 min (dilution + 5 min)
Demineralised water: For rinsing / dilution
Earth connection: Dry and clean earth pole with low impedance (< 1 Ohm) using an earth cable of > 2.5 mm²
Gwarancja: 24 miesięcy
Instrument air: Dry and oil free according to ISA-S7.0.01-1996 quality standard for instrument air
Jakość próbki: Maximum particle size 100 µm, < 0.1 g/L; Turbidity < 50 NTU
Kalibracja: Automatic, 2-point; frequency freely programmable
Klasa ochrony: Protection class: Analyser cabinet: IP44 / Panel PC: IP65
Liczba strumieni próbki: 1, 2, 4, or 8
Limit detekcji: ≤ 20 µg/L
Materiał: Hinged part: Thermoform ABS, door: PMMA
Wall section: Galvanised steel, powder coated
Metoda pomiarowa: Colorimetric measurement using vanadate yellow method (450 nm)
Model: EZ1031
Odpływ: Atmospheric pressure, vented, min. Ø 32 mm
Parametr: Orthophosphate (PO₄-P)
Pobór mocy: 100 - 240 VAC, 50/60 Hz
Max. power consumption: 120 VA
Precyzja: Better than 3% full scale range for standard test solutions
Prędkość przepływu: 100 - 300 mL/min
Reagent Requirements: Keep between 10 - 30 °C
Temperatura otoczenia: 10 - 30 °C ± 4 °C deviation at 5 - 95% relative humidity (non-condensing)
Temperatura próbki: 5 - 30 °C
Validation: Automatic; frequency freely programmable
Waga: 25 kg
Wyjścia analogowe: Active 4 - 20 mA max. 500 Ohm load, standard 1, max. 8 (option)
Wyjścia cyfrowe: Optional: Modbus (TCP/IP, RS485)
Wymiary (wys. x szer. x głęb.): 690 mm x 465 mm x 330 mm
Zakłócenia: Positive interference is caused by Silica Arsenate if the sample is heated. Negative interferences are caused by Arsenate, Fluoride, Thorium, Bismuth, Sulphide, Thiosulphate, Thiocyanate or excess of Molybdate. Blue colour is caused by Ferrous Iron but this does not affect results for Ferrous Iron concentrations < 100 mg/L. If Nitric Acid is used, Chloride interferes from 75 mg/L. Large amounts of colour and turbidity interfere. Fats, oil, proteins, surfactants and tar.
Zakres pomiarowy: 0.1 - 10 mg/L PO₄-P
  0.1 - 10 mg/L PO₄-P

Optional:
0.02 - 1 mg/L
0.05 - 2.5 mg/L
0.05 - 5 mg/L
0.8 - 40 mg/L (with internal dilution)
1.6 - 80 mg/L (with internal dilution)
10 - 1000 mg/L (with internal dilution)
Zasilanie: 100 - 240 VAC, 50/60 Hz
Zawartość opakowania: EZ1031 Phosphate Analyser, Instruction Manual, 1 x Double Bit Door Key, 1 x Mounting Brackets and 1 x empty 2.5L Reagent Container with Fittings (for Colour Solution)